Technology Database Prospecting, production activity and waste handling of minerals Petroleum-gas machinery INSULATION CONTROL DEVICE
INSULATION
CONTROL DEVICE
Insulation quality control device
is used to control quality of electric cable and electric motor insulation at
the wells equipped with submersible centrifugal pump units at environment
temperatures down to -40°C.
The main components
of the device are: electric battery, converter and analyzer.
Control of the device is
accomplished with switch (1), mode operation switch (2), discharge
button (3), "Cable Test" button (4), "Cable &
Motor Test" button (5), light indicator (6), and sound
signalizer (7). For high voltage insulation quality control (up to 10 kV)
in resistance range up to 400 Mohm the first clip (1K) is connected with cable
sleeve, and the second one (2K) - with one of the phase wirings. In the process
of roundtrip operations insulation quality control is performed simultaneously
by low voltage with maximum current 25 mA by connecting the equipment being
checked to clips 1K and 3K. If insulation resistance is lower than minimum
allowable value, then light and sound indications turn on. Pickup threshold is
established in laboratory conditions using standard resistance.
Source: SciTecLibrary.ru
Publishing date: December 27, 2000
To make an inquiry on the technology you are interested in
Back
|  |