"What must a motor control be capable of?"
This is the constant question for
system engineers. The answer determines the required performance.
"All in one"
is at first glance a good advertising slogan, but for the customer it can be an
expensive and unnecessary solution. Achieving maximum performance from minimal
investment is the basic goal of the F4 and S4 inverter
series. The performance levels make it possible to create the optimum solution:
- basic variable speed – F4-s;
- application specific programming – F4-c;
- optimum control of induction motors with
regulated field oriented control – F4-f;
- maximum dynamic performance with the AC servo
series – S4.
You can be assured of easy
startup with limited personnel training due to simple parameter structure,
uniform connection, low profile mounting technique.
The following communication
protocols are supported: INTERBUS and
InterBus Loop, Profibus DP/FMS, CAN, LON, DIN66019.
The versatile frequency
inverter KEB COMBIVERT F4-C
The versatile frequency inverter
in the power range
0.75... 250 kW
User friendly handling via the CP
front and menu as well as the application menu for more demanding
requirements:
- Accel / decel curves
- DC injection braking
- Speed search / Flying start
- LAD stop
- Autoboost / Sensorless Vector Control
- Slip compensation
- Voltage stabilization

- Preset speeds
- Integrated timer
- Hardware current control
- Pi-control
- Power-off function closed loop speed control
can be activated in 8 different parameter-sets by
free programmable hardware and software inputs and outputs.
±10 V input
with minimum scan times allow servo features for the standard motor.
Removable operator
modules for handling and display as well as different serial interfaces
ensure the flexible adaptation to your requirements.
The Problem solving inverter - KEB COMBIVERT F4-C
Technical Data Power-Circuit
|
230 V |
Inverter without filter |
Inverter with internal filter |
filter kit |
INPUT |
OUTPUT |
DIM.
 õ Í õ Ò [mm] |
|
Size |
|
Voltage (50/60Íz)2)
[V] |
Phases |
Current [À] |
Max. motor raiting1) [kW] |
Nominal
power [kWA] |
Rated current [À] |
Peak current (30sec.)[À]
|
Voltage [V] |
Frequency/Resolution |
Inverter without filter |
Inverter with internal filter |
filter kit |
|
1 fhase
|
3 fhase |
|
07. |
F4.C1D-1280 |
F4.C3D-1280 |
- |
200/208/220/230/240
(180…264± 0%) |
· |
Î |
8 |
0,75 |
1,6 |
4,0 |
7,2 |
3õ0…Umains |
0…816 Hz/ digital. 15Bit/ analog. 10
Bit |
90õ250õ160 |
90õ265õ210 |
- |
|
09. |
F4.C1D-1220 |
F4.C3D-1220 |
- |
· |
Î |
14 |
1,5 |
2,8 |
7,0 |
12,6 |
|
10. |
F4.C1D-1280 |
F4.C3D-1280 |
- |
· |
Î |
20 |
2,2 |
4,0 |
10 |
18 |
|
13. |
F4.C1E-3220 |
- |
U4.00E-ÂÀÎÎ |
- |
· |
26.5 |
5,5 |
8,3 |
24 |
36 |
130õ290õ200 |
- |
180õ415õ55 |
|
14. |
F4.C1G-3280 |
- |
U4.00G-ÂÀÎÎ |
- |
· |
36.5 |
7,5 |
11 |
33 |
49,5 |
170õ340õ255 |
- |
|
15. |
F4.C1H-3280 |
- |
16.U4.00H-ÂÀÎÎ |
- |
· |
|
11 |
17 |
75 |
|
297õ340õ255 |
-
|
300õ455õ65 |
|
16. |
- |
· |
|
15 |
23 |
90 |
|
|
400 V |
Inverter without filter |
Inverter with internal
filter |
filter kit |
INPUT |
OUTPUT |
DIM.
 õ Í õ Ò [mm] |
|
Size |
|
Voltage (50/60Íz)2)[V] |
Current
[À] |
Max. motor raiting1) [kW] |
Nominal power [kWA] |
Rated current [À] |
Peak current (30sec.) [À]
|
Voltage
[V] |
Frequency/Resolution |
Inverter without filter |
Inverter with internal
filter |
filter kit |
|
07. |
F4.C1D-3240 |
F4.C3D-3240 |
- |
3ph. 380/400/220/230/240
(180…264± 0%) |
2,8 |
0,75 |
1,8 |
2,6 |
4,6 |
3õ0…Umains
|
0…816 Hz/digital. 15 Bit /
analog. 10 Bit |
90õ250õ160 |
90õ265õ210 |
- |
|
09. |
- |
4,5 |
1,5 |
2,8 |
4,1 |
2,8 |
4,1 |
7,4 |
|
10. |
F4.C1D-3460 |
F4.C3D-3460 |
- |
6,4 |
2,2 |
4,0 |
5,8 |
10,4 |
|
12. |
F4.C1D-3420 |
F4.C3D-3420 |
- |
10,5 |
4,0 |
6,6 |
9,5 |
17,1 |
|
13. New |
F4.C1D-3410 |
F4.C3D-3410 |
- |
13,2 |
5,5 |
8,3 |
12 |
21,6 |
|
14. |
F4.C1E-3440 |
- |
U4.00E-ÂM00 |
18,1 |
7,5 |
11 |
16,5 |
29,7 |
130õ290õ200 |
- |
130õ352õ50 |
|
15. |
F4.C1H-3280 |
- |
26,5 |
11 |
17 |
24 |
36 |
|
16. |
F4.C1G-3440 |
- |
16.U4.00G-BM00 |
36,3 |
15 |
23 |
33 |
49,5 |
170õ340õ255 |
180õ415õ55 |
300õ445õ65 |
|
17. New |
F4.C1G-3420 |
- |
46,7 |
18,5 |
29 |
42 |
63 |
|
18. |
F4.C0H-3440 |
- |
U4.00H-ÂM00 |
55 |
22 |
35 |
50 |
75 |
|
19. |
F4.C0H-3420 |
- |
66 |
30 |
42 |
60 |
90 |
3õ0…Umains |
0…816 Hz/digital. 15 Bit / analog. 10 Bit
|
297õ340õ255 |
- |
300õ445õ65 |
|
20. New |
F4.C0R-3440 |
F4.C2R-3440 |
- |
82,5 |
37 |
52 |
75 |
112,5 |
340õ520õ355 |
340õ520õ355 |
340õ520õ355 |
|
21. New |
F4.C0R-3420 |
F4.C2R-3420 |
- |
99 |
45 |
62 |
90 |
135 |
|
22. New |
F4.C0R-3420 |
F4.C2R-3420 |
- |
126,5 |
55 |
80 |
115 |
172,5 |
|
23. New |
F4.C0R-3410 |
- |
U4.0LM-ÂM00 |
165 |
75 |
104 |
150 |
225 |
|
- |
110õ438õ240 |
|
24. |
F4.C0M-3440 |
- |
25.U4.0MN-ÂM00 |
198 |
90 |
125 |
180 |
225 |
412õ616õ377 |
- |
110õ478õ240 |
|
25. |
F4.C0N-3420 |
- |
237 |
110 |
145 |
210 |
262,5 |
510õ824õ356 |
- |
|
26. |
|
27.U4.0NP-ÂM00 |
275 |
132 |
173 |
250 |
312,5 |
300õ564õ160 |
|
27. |
F4.C0P-3410 |
- |
330 |
160 |
208 |
300 |
375 |
510õ824õ408 |
340õ520õ355 |
|
28. |
U4.00P-ÂM00 |
410 |
200 |
256 |
370 |
462,5 |
|
29. |
|
510 |
250 |
319 |
460 |
575 |
|
Immunity/
Emitted interference |
Product norm: EN 61800-3/
limit values according to
EN 50082-2/ EN 50081-2 with filter |
|
Options |
Line reactor; motor choke,
sinus output filter; braking resistor;switching frequency depending on size up
to 16 kHz; output frequency 1600 Hz;closed loop speed control with tacho,
encoder or puls feedback |
|
Type of protection |
IP 20 |
|
Temperature:
during operation |
-10…+450Ñ |
|
storage |
-25…+700Ñ |
F4-S - an
inverter with many possibilities
-
Preadjusted basic unit in a control cabinet with
cover and status display and fault indicator.
- Operation and indication by means of the DIGITAL
OPERATOR 00.F4.010-2009
-
Additionally with isolated serial RS232/485
interface on Sub-min D-connector with the INTERFACE OPERATOR 00.F4.010-1009
 
Basic operator and programming
station MEMORY OPERATOR 00.F4.010-3009 pluggable,
universal data medium for easy to service customer settings - in connection with
the COMBICARD SYSTEM 00.F4.000-3009 a safe tool for
the unit parameterizing.
Field bus communication in
interconnection with PLC or PC is done via pluggable serial interface modules.


Publishing date: November 24, 2000
To make an inquiry on the technology you are interested in