Production of an industry    Electronics engineering A GALVANIC DECOUPLING DEVICE (UGR) AS A METER OF DC FEEDER LOADS

A GALVANIC DECOUPLING DEVICE (UGR) AS A METER OF DC FEEDER LOADS

A galvanic decoupling device (UGR) is meant for the following:

1. To measure and transmit to the ground potential (while producting a high level analogue signal) a signal from a standart DC 75 mV shunt being under hight potential.

2. To transmit any normalised analogue signals from electric circuits under high potential, e.g. from 3,3 kV DC voltage dividers, over to the ground potential.

The device is made to have a high voltage insulator (executed from caprolon) through which the power at high potential is supplied onto a converter of an input analogue signal (coming from a divider or shunt) onto pulse frequency, and in the reverse direction a frequency pulse signal goes through an infrared optic channel. The device also has a frequency-to-voltage converter to extract the analogue signals. Another infrared optic channel (also mounted in the insulatir) is used to test the UGR operation.

TECNICAL CHARACTERISTICS:

 

Range of measured currents ...........................................................

...... 0...40 kA

Range of input voltage ...............................................................

..... 0...1V

Voltage of isolation ...................................................................

......>= 20 kV

Output voltage on load 1 kO in range of currents < 4 kA ...........

......0...10V

Output voltage on this channel in range of currents from 4 kA up to 40 kA ...

.....1...10V

Output frequency in all ranges of current and voltage ...............

......0...100 kHz

Error of measurements..............................................................

......±1%

Size ............................................................................................

......280x120x180 mm

Weight ......................................................................................

......<= 2kg

Consumed network (220 V, 50 Hz) ...........................................

......<= 3W

Galvanic decouping network (220 V, 50 Hz) voltage .................

......>= 4000V

Workability test mode is availabel.

Country: Russia
Source: SciTecLibrary.ru
Publishing date: September 12, 2000

To make an inquiry on the production you are interested in

Back

 

Copyright © SciTecLibrary


To add the material   Terms of registration   Terms for placing technology, inventions, productions & other informations   Price list




Rambler's Top100 Rambler's Top100 ßíäåêñ öèòèðîâàíèÿ